It
is known fact that the usage of convention steam
sterilization process for terminal sterilization
of liquids in plastic bottles/flexible plastic
bags can result in it getting deformed the stoppers
getting loosened or even breaking due to internal
over pressure.
All
the above mentioned problems are overcome in
Pharmalab's
Super Heated Water Spray Sterilizer. Heating
and cooling is done with circulating water in
a closed system. The main benefit of using water
as the heat transfer medium is that the process
sterilizes the water along with the product and
therefore present no hazard to the product. Any
suitable type of water, namely, de-mineralized
water or WFI may be used. The water gets heated
by passing through the exchanger, which is then
sprayed on the product through the nozzles from
the upper part of the chamber. High water flow
rated also ensure that uniform temperature distribution
is maintained throughout the chamber during the
sterilization phase. During
the cooling phase, the heat exchanger is fed with
cooling medium and the circulating water gets
cooled, which in turn is sprayed onto the product,
thus reducing its temperature to the desired level.
A sterile air overpressure is maintained during
all the phases.
|